Specialist groundwater field services · Australia wideConfidence starts in the field.
Home / Groundwater Monitoring & Sampling

Groundwater Monitoring & Sampling

Groundwater monitoring & sampling.
One integrated field service.

Soltera delivers groundwater level monitoring, logger programs and representative groundwater sampling as one coordinated service—supported by calibrated instrumentation, field QA/QC, laboratory coordination and hydrogeological understanding.

Fit-for-purpose monitoring

Start with the questions the monitoring program must answer.

Effective monitoring begins before a bore is dipped or a sample is collected. We review the site, the available evidence and the groundwater risks so the monitoring network is designed around the hydrogeological system and the decisions the data need to support.

01

Desktop review

Site history, geology, hydrogeology, existing bore records, historical groundwater levels and quality, previous reports, licences and operational information.

02

3D conceptual model

Integration of bore logs, stratigraphy, groundwater elevations, aquifers, aquitards, sources, pathways and receptors using specialist tools such as Seequent Leapfrog where appropriate.

03

Network design

Monitoring bore numbers and locations based on groundwater flow, source areas, background conditions, site boundaries, receptors and data gaps.

04

Bore design

Target aquifer, bore depth and screen interval recommendations informed by hydrostratigraphy, groundwater levels, vertical gradients and the monitoring objective.

05

Monitoring frequency

Manual, continuous, monthly, quarterly, six-monthly, annual or event-based monitoring selected to capture meaningful groundwater behaviour.

06

Parameters & analytes

Field and laboratory parameters selected around site history, potential contaminants of concern, background chemistry, compliance requirements and receptor risk.

Field delivery

Then we take the program into the field.

Soltera delivers the recurring monitoring work with consistent methods, calibrated equipment, field QA/QC and the hydrogeological awareness to recognise when something does not look right.

01

Measure

Manual groundwater levels from defined reference points and field condition observations.

02

Instrument

Logger supply, installation, programming, downloads, maintenance and manual verification.

03

Sample

Low-flow and fit-for-purpose sampling, field parameters, preservation and chain of custody.

04

Control

Calibration, field QA/QC, bore inspections, contamination controls and traceable records.

05

Coordinate

Laboratory logistics, analytical schedules, data receipt and monitoring-round handover.

Groundwater sampling

Representative sampling integrated with the monitoring round.

Sampling is delivered as part of the same controlled monitoring system—so water levels, bore condition, field parameters, sampling observations, QA/QC and laboratory handover remain connected in one traceable field record.

Low-flow and project-specific sampling methods where appropriate
Controlled pumping, drawdown and parameter stabilisation
pH, EC, temperature, dissolved oxygen, ORP and turbidity
Duplicates, blanks, decontamination and contamination controls
Preservation, chain of custody and NATA-accredited laboratory coordination where required
Site-specific analytical suites for landfill, mining, industrial and contaminated-land programs
Groundwater field technician collecting a groundwater sample beside a monitoring bore
Monitoring & samplingOne coordinated groundwater field round.

Loggers & instrumentation

Continuous groundwater information when it matters.

Soltera can supply, install and manage groundwater monitoring instrumentation as part of an integrated monitoring program.

Water-level logger and pressure transducer supply
Barometric logger deployment where required
Installation depth and logger configuration
Manual verification measurements and reference checks
Routine downloads, maintenance and continuity checks
Telemetry-ready monitoring options where appropriate
MONITORING SYSTEM
Manual levelVerification & reference
LoggerContinuous pressure / level
BarometerAtmospheric compensation
Field recordCondition & metadata
DatabaseProcessed & traceable

Data processing & QA/QC

Raw logger files are not the finished groundwater record.

Continuous monitoring data require systematic technical checks before they are interpreted. Soltera can process and quality-control logger records while preserving traceability back to the original data.

Barometric compensation

Atmospheric pressure correction using appropriate barometric records and documented processing methods.

Manual dip verification

Comparison of logger response against manual measurements to identify offsets, drift or installation issues.

Time, datum & reference checks

Timestamp, clock, measuring-point elevation, logger depth and unit consistency checks before hydrographs are generated.

Density / salinity correction

Where elevated salinity materially affects pressure-to-head conversion, groundwater density can be considered in the processing approach.

Data quality review

Outlier, gap, sensor drift, step-change and anomalous-response checks with documented adjustments where justified.

Groundwater elevation

Conversion of verified measurements to consistent groundwater elevations for comparison across the monitoring network.

Groundwater data management

One place for the monitoring record.

Soltera can organise long-term monitoring information into a structured groundwater database and project dashboard so clients can see, track and use the data without searching across disconnected spreadsheets and historical reports.

Groundwater levels and hydrographs
Field parameter trends
Laboratory analytical results
Bore construction and monitoring metadata
Trigger / compliance comparisons where required
Downloadable and printable charts and datasets
Data & dashboard capability →
GROUNDWATER MONITORINGSite overview
BH01BH04BH08
BORESNetwork
LEVELSHydrographs
QUALITYTrends

Hydrographs & interpretation

Make groundwater behaviour easy to see.

Clear visualisation makes long-term change easier to identify. Where required, monitoring data can be compared with rainfall, pumping, operations, trigger levels and groundwater chemistry to support technical interpretation.

A

Groundwater hydrographs

Depth-to-water and groundwater elevation time series with consistent bore naming, datum and monitoring context.

B

Water-quality trends

Parameter trends, spatial comparisons, trigger levels and identification of emerging changes across monitoring rounds.

C

Integrated interpretation

Comparison with rainfall, recharge, pumping, site operations and other relevant datasets where the monitoring question requires it.

A complete monitoring partner

Design it. Monitor it. Manage it. Understand it.

Talk to Soltera about a new monitoring program, an existing network that needs improvement, or a long-term dataset that needs to become more useful.

Discuss your monitoring program →